28 AWG, 80C, MULTICONDUCTOR, MAGNASHIELD (DUAL SIDED FOIL/BRAID)

-
Color Codes
Chart C
Cond. No. Color Code Cond. No. Color Code 1 Black 26 White/Black/Green 2 Red 27 White/Black/Yellow 3 White 28 White/Black/Blue 4 Green 29 White/Black/Brown 5 Orange 30 White/Black/Orange 6 Blue 31 White/Black/Slate 7 Brown 32 White/Black/Purple 8 Yellow 33 White/Black/Black 9 Purple 34 White/Red/Black 10 Slate 35 White/Red/Red 11 Pink 36 White/Red/Green 12. Tan 37 White/Red/Blue 13 Red/Green 38 White/Red/Brown 14 Red/Yellow 39 White/Red/Purple 15 Red/Black 40 White/Green/Black 16 White/Black 41 White/Green/Red 17 White/Red 42 White/Green/Green 18 White/Green 43 White/Green/Blue 19 White/Yellow 44 White/Green/Brown 20 White/Blue 45 White/Green/Purple 21 White/Brown 46 White/Blue/Black 22 White/Orange 47 White/Blue/Red 23 White/Gray 48 White/Blue/Green 24 White/Violet 49 White/Blue/Blue 25 White/Black/Red 50 White/Blue/Brown -
MAGNAShield Cable Shielding
MAGNAShield Cable Shielding: The proper shielding of electrical cables is paramount to overall system performance. Many applications now require shielding that is more effective than aluminum foil or tinned copper braid. In response to this demand, WEICO has created MAGNAShield. Employing a triple laminated foil shield (foil/polyester/foil) with drain wire plus tinned copper braid, MAGNAShield virtually eliminates the effects of radiated signals (EMI/RFI) and electrostatic discharges.
Providing a 100% increase in shielding effectiveness over braid alone. MAGNAShield exceeds the requirements of FCC Docket 20780, MIL STDS 461 & 462B and Tempest.

MULTICONDUCTOR
MAGNASHIELD
80º - 300V
DESCRIPTION:
Each Conductor Stranded (7/36) Tinned Copper, Nominal Insulation Thickness .010", Color Coded Semi-Rigid Polyvinylchloride Insulation, MAGNAShield (Aluminum Foil/ Polyester/Aluminum Foil with Drain Wire and Tinned Copper Braid) Gray PVC Jacket Overall.
SPECIFICATIONS:
- UL Listed, NEC Type CL2, 75°C, 150V
- UL AWM Style 2464, 80°C, 300V
- CSA Certified PCC FT-4
- Meets FCC Docket 20780
- MIL-STD 461 & MIL STD 462B and Tempest
*Click on a part number below for pricing and ordering online
Min Temperature | -30°C |
---|---|
Max Temperature | 80°C |
Voltage | 300V |
Special | No |
Weico No. | AWG SIZE | NO. OF CONDUCTORS | NOM. JACKET THICKNESS (INCHES) | NOM. O.D. (IN) | |
---|---|---|---|---|---|
9103/28* | 28 | 3 | 0.035 | .16 | |
9104/28 | 28 | 4 | 0.035 | .17 | |
9105/28 | 28 | 5 | 0.035 | .18 | |
9106/28 | 28 | 6 | 0.035 | .19 | |
9107/28 | 28 | 7 | 0.035 | .19 | |
9108/28 | 28 | 8 | 0.035 | .21 | |
9109/28 | 28 | 9 | 0.035 | .22 | |
9110/28 | 28 | 10 | 0.035 | .23 | |
9115/28 | 28 | 15 | 0.035 | .26 | |
9125/28 | 28 | 25 | 0.035 | .30 | |
9137/28 | 28 | 37 | 0.035 | .34 | |
9150/28 | 28 | 50 | 0.035 | .40 |
*AWM Only
Standard Put-Ups: 100 ft., 500 ft., 1000 ft.