BT, TUBULAR BRAID, QQ-B-575 R, ASTM-B-33, TINNED COPPER TUBULAR BRAID

Description

TUBULAR BRAID QQ-B-575 R

ASTM-B-33

DESCRIPTION:

Tinned Copper Brid Woven in Completely Round Configuration as Outlined in SPEC QQ-B-575.

APPLICATION:

Used As Both Shielding and Protective Covering.  Shielding is 95% Or More When Placed Over Equivalent Diameter Mandrel To The Inside Diameter of Tubular Braid.

*Click on a part number below for pricing and ordering online

Min Temperature No
Max Temperature No
Special No
Buy Now Select A Part Number
Weico No. MILITARY NO. QQB575R **NOM. I.D. AWG. OF INDIV. ENDS CARRIERS TOTAL NO. OF INDIV. ENDS APPROX. AWG EQUIV. NOM. CIRC. MILLS * CURRENT CARRYING CAP. (AMPS)  
BT-1/32 36T031 1/32 36 24 24 22 600 7.0
BT-1/16 36T062 1/16 36 24 48 19 1200 11.0
BT-5/64 36T078 5/64 36 24 72 18 1800 16.0
BT-7/64 36T109 7/64 36 24 96 16 2400 19.0
BT-1/8 36T125 1/8 36 24 120 15 3000 25.5
BT-5/32 36T156 5/32 36 24 240 12 6000 40.0
BT-11/64 36T171 11/64 36 24 168 14 4200 32.0
BT-13/64 34T203 13/64 34 24 192 11 7630 46.0
BT-1/4 36T250 1/4 36 24 384 10 9600 53.0
BT-9/32 30T281 9/32 30 24 120 9 12060 60.0
BT-3/8 36T375 3/8 36 48 384 10 9600 53.0
BT-7/16 30T437 7/16 30 24 240 6 24120 90.0
BT-1/2 36T500 1/2 36 48 528 9 13200 62.0
BT-9/16 30T562 9/16 30 48 480 3 48240 145.
BT-21/32 30T656 21/32 30 48 768 1 77180 190.
BT-25/32 36T781 25/32 36 48 864 7 21600 88.0
BT-1 30T1000 1 30 48 384 4 38600 120.
*Values shown are for bare cable in free air at 30C (86F) and intended as a reference guide only. Actual values will depend on permissible temperature rise, permissible voltage and other conditions of service.
**When Rounded
Standard Put-Ups: 100 ft., 500 ft., 1000 ft.